Component Location
■ Binary
■ Linear
General Description
■ Binary

The normal operating temperature of the HO2S(Heated Oxygen Sensor) ranges from 350 to 850℃(662 to 1562℉). The HO2S heater greatly decreases the amount of time required for fuel control to become active. The PCM provides a pulse width modulated control circuit to adjust current through the heater. When the HO2S is cold, the value of the resistance is low and the current in the circuit is high. On the contrary, if the temperature in the resistor of the sensor rises, the current drops gradually.

■ Linear

The normal operating temperature of the HO2S(Heated Oxygen Sensor) ranges from 350 to 850℃(662 to 1562℉). The HO2S heater greatly decreases the amount of time required for fuel control to become active. The PCM provides a pulse width modulated control circuit to adjust current through the heater. When the HO2S is cold, the value of the resistance is low and the current in the circuit is high. On the contrary, if the temperature in the resistor of the sensor rises, the current drops gradually.

DTC Description
■ Binary

PCM sets DTC P0031 if the PCM detects that the front HO2S heater control circuit is short to ground.

■ Linear

PCM sets DTC P0031 if the PCM detects that the front HO2S heater control circuit is short to ground.

DTC Detecting Condition
Binary

Item

Detecting Condition

Possible Cause

DTC Strategy

Electrical Check

1.

Related fuse blown or missing

2.

Open or short to ground in power supply or control harness

3.

Poor connection or damaged harness

4.

Faulty HO2S

Enable Conditions

No relevant failure

10V< Battery voltage <16V

3.5%< O2 sensor heater control duty <96.5%

Threshold Value

HO2S Heater Output < Lower Threshold

Diagnostic Time

10 sec.

Mil On Condition

2 Driving Cycles

Linear

Item

Detecting Condition

Possible Cause

DTC Strategy

Electrical Check

1.

Related fuse blown or missing

2.

Open or short to ground in power circuit

3.

Short to ground in control circuit

4.

Poor connection or damaged harness

5.

Faulty HO2S

Enable Conditions

10V < Battery voltage < 16Vs

1.5% < Heater power < 98.5%

Exhaust gas Temp. > 300°C (572℉)

Threshold Value

Short to ground

Diagnostic Time

1 sec.

Mil On Condition

2 Driving Cycles

Specification
Binary

Temp.(℃)

Temp.(℉)

Heater Resistance (Ω)

18 ~ 20

64 ~ 82

3.3 ~ 4.1

Linear

HO2S Heater

Normal Parameter

18 ~ 20℃

Heater Resistance

3.2±0.8 Ω

Diagnostic Circuit Diagram

BINARY

LINEAR

Яндекс.Метрика