Component Location
■ Linear
General Description

The linear O2 sensor is mounted on the front side of the Catalytic Converter (warm-up catalytic converter) or in the front exhaust pipe. It detects a wide range of air/fuel ratios in the exhaust gas from the rich to lean regions. This linear O2 sensor produces a current that corresponds to a specific air/fuel ratio. The PCM monitors this signal and determines whether the air/fuel mixture is rich or lean. The PCM constantly monitors the linear O2 sensor and increases or decreases the fuel injection duration using this signal. This is called closed-loop fuel control operation.

DTC Description

If the HO2S signal voltage is fixed at rich status, then feedback control is no longer possible, the PCM sets DTC P2196.

DTC Detecting Condition

Item

Detecting Condition

Possible cause

DTC Strategy

Characteristic line middle shift

1.

Poor connection or damaged harness

2.

Front HO2S

Enable Conditions

No relevant failure

10volt < battery voltage < 16 volt

Threshold value

Active test symptom during shift of lambda setpoint to rich or lean ( after P2096 / P2097 detection)

Diagnosis Time

10 sec

MIL On Condition

2 driving cycle

Diagnostic Circuit Diagram