Terminal and connection inspection
1.

Many malfunctions in the electrical system are caused by poor harness(es) and terminals. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.

2.

Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.

3.

Has a problem been found?

▶ Repair as necessary and go to "Verification of Vehicle Repair" procedure.

▶ Check for poor connection between PCM and component: backed out terminal, improper mating, broken locks or poor terminal to wire connection. Repair as necessary and go to "Verification of Vehicle Repair" procedure.

Power Circuit Inspection
■ Check for Short to Ground in Power circuit
1.

IG KEY OFF.

2.

Disconnect VIS Sol. valve harness connector.

3.

Measure resistance between power terminal of VIS. Sol valve harness connector and chassis ground.

Specification : Infinite

4.

Is resistance within specification?

▶ Go to next procedure.

▶ Repair as necessary and go to "Verification of Vehicle Repair" procedure.

■ Check for Open in Power circuit
5.

IG KEY OFF.

6.

Disconnect VIS Sol. Valve harness connector.

7.

IG KEY ON.

8.

Measure voltage between power terminal of VIS Sol. Valve harness connector and chassis ground.

Specification : Approx. 12V

9.

Is voltage within specification?

▶ Go to next procedure.

▶ Repair as necessary and go to "Verification of Vehicle Repair" procedure.

Control Circuit Inspection
■ Check for Open/Short to Ground in Cotrol circuit
1.

IG KEY OFF.

2.

Disconnect VIS Sol. Valve harness connector.

3.

IG KEY ON.

4.

Measure voltage between control terminal of VIS Sol. Valve harness connector and chassis ground.

Specification : Approx. 4.5 V

5.

Is voltage within specification?

▶ Go to next procedure.

▶ Repair as necessary and go to "Verification of Vehicle Repair" procedure.