Monitoring rail pressure data
Connect GDS to Data Link Connector (DLC).
Warm engine up to normal operating temperature.
Turn "OFF" electrical devices and A/C.
Monitor "FUEL PRESSURE MEASURED", "FUEL PRESSURE-TARGET", "RAIL PRESS. REGULATOR1", "INJ. PUMP REGULATOR" parameter on the GDS.
Fig.1) Monitor "FUEL PRESSURE MEASURED" at idle after warming engine up.
Monitoring rail pressure data at acceleration(loading condition).
Connect GDS to Data Link Connector (DLC).
Warm engine up to normal operating temperature.
Turn "OFF" electrical devices and A/C.
Monitor "FUEL PRESSURE MEASURED", "RAIL PRESS. REGULATOR1", "INJ. PUMP REGULATOR" parameter on the GDS.
Idle(without load) | Accelerating(stall test) | Diagnosis | |
INJ. PUMP REGULATOR | 38 ± 5% | 32 ± 5% | duty decreases |
FUEL PRESSURE MEASURED | 28.5 ± 5 Mpa | 145 ± 10 Mpa | press. increases |
Fig.1) Fuel pressure When accelelating.