Monitor GDS Data
1.

Connect GDS to Data Link Connector (DLC).

2.

Warm engine up to normal operating temperature.

3.

Turn "OFF" electrical devices and A/C.

4.

Monitor "GLOW RELAY" parameter on the GDS.

Specification :

After operating according to engine coolant temperature and battery voltage, Glow relay turns "OFF".

At IG KEY "ON". (Refer to Specification)

Fig.1) Operating state of Glow relay is shown. However, it is difficult to check operating state because Glow relay turns OFF 2~3 sec. after operation at normal temp.

Fig.2) Checking glow relay operation and power supply to glow plug using "ACTUATION TEST" on GDS is convenient.