System Inspection
■ Check Generator circuit
1.

Engine starts.

2.

Maintain ENG RPM 2,500RPM over 2 minutes.

3.

Measure voltage between the battery terminal(+) and the battery terminal(-).

Specification : Approx. 12.5 ~ 14.7V

4.

Is the measured voltage within specification?

▶ Substitute with a known - good battery sensor and check for proper operation. If the problem is corrected, replace battery sensor and go to "Verification of Vehicle Repair" procedure.

▶ Check that the tension of drive belt, ENG RPM, fuse, terminal of battery, all terminals of generator are in good condition and Check for damaged harness and poor connection between generator and battery. If OK repair or replace generator and then go to "Verification of vehicle Repair" procedure.