Inspection
1.

Turn the ignition switch OFF.

2.

Disconnect the intake actuator connector.

3.

Verify that the intake actuator operates to the fresh position when connecting 12V to the terminal 3 and grounding terminal 4.

Verify that the intake actuator operates to the recirculation position when connecting in the reverse.

1. -                 

2. –                  

3. Fresh              

4. Recirculation

5. Sensor (+ 5V)

6. Feedback Signal

7. Sensor Ground

4.

Connect the intake actuator connector.

5.

Turn the ignition switch ON.

6.

Check the voltage between terminal 6 and 7.

Specification

Door position

Voltage (V)

Error detecting

Max. cooling

0.5 ± 0.15V

Low voltage : 0.1V or less

Max. heating

4.5 ± 0.15V

High voltage : 4.9V or more

7.

If the intake actuator is not operated well, substitute with a known-good intake actuator and check for proper operation.

8.

If the problem is corrected, replace the intake actuator.

Replacement
1.

Disconnect the negative (-) battery terminal.

2.

Remove the crash pad.

(Refer to BD group - "Crash Pad")

3.

Disconnect the connector (A) and then remove the intake actuator (B) after loosening the mounting screws.

4.

Install in the reverse order of removal.