Inspection
1.

Turn the ignition switch OFF.

2.

Disconnect the auto defogging connector.

3.

Verify that the auto defogging actuator operates to the open position when connecting 12V to the terminal 3 and grounding terminal 4.

Verify that the auto defogging actuator operates to the close position when connecting in the reverse.

1. -

2. -

3. Open

4. Close

5. Sensor ground

6. Feedback signal

7. Sensor (+ 5V)

4.

Connect the auto defogging actuator connector.

5.

Turn the ignition switch ON.

6.

Check the voltage between terminals 6 and 5.

Door position

Voltage (V)

Error detecting

Defog OFF (Close)

0.3 ± 0.15V

Low voltage :0.1V or less

Defog ON (Open)

4.7 ± 0.15V

High voltage :4.9V or more

It will feedback current position of actuator to controls.

7.

If the measured voltage is not specification, substitute with a known-good auto defogging actuator and check for proper operation.

8.

If the problem is corrected, replace the auto defogging actuator.

Replacement
1.

Disconnect the negative (-) battery terminal.

2.

Remove the crash pad.

(Refer to BD group – “Crash pad”)

3.

Disconnect the connector (A) and then remove the auto defogging actuator (B) after loosening the mounting screws.

4.

Install in the reverse order of removal.

Яндекс.Метрика