Inspection
1.

Turn the ignition switch OFF.

2.

Disconnect the mode control actuator connector.

3.

Verify that the mode control actuator operates to the defog mode when connecting 12V to the terminal 3 and grounding terminal 4.

Verify that the mode control actuator operates to the vent mode when connecting in the reverse.

1. -

2. -

3. Defog mode

4. Vent mode

5. Sensor ground

6. Feedback signal

7. Sensor (+ 5V)

4.

Connect the mode control actuator connector.

5.

Turn the ignition switch ON.

6.

Check the voltage between terminal 6 and 5.

Specification

Door position

Voltage (V)

Error detecting

Max. cooling

0.3 ± 0.15V

Low voltage : 0.1V or less

Max. heating

4.7 ± 0.15V

High voltage : 4.9V or more

It will feedback current position of actuator to controls.

7.

If the measured voltage is not specification, substitute with a known-good mode control actuator and check for proper operation.

8.

If the problem is corrected, replace the mode control actuator.

Replacement
1.

Disconnect the negative (-) battery terminal.

2.

Remove the driver side crash pad side cover (A).

3.

Remove the crash pad garnish (A) after loosening the mounting screws.

4.

Remove the crash pad lower panel (A) after loosening the mounting screws and then disconnect the connectors (B).

5.

Remove the driver side crash pad under cover (A) and then disconnect the connector (B).

6.

Remove the driver side shower duct (A) after loosening the screw.

7.

Remove the accelerator pedal.

(Refer to FL group - “Accelerator Pedal”)

8.

Disconnect the connector (A) and then remove the mode control actuator (B) after loosening the mounting screws.

9.

Install in the reverse order of removal.

Яндекс.Метрика