Inspection
1.

Turn ignition switch OFF.

2.

Disconnect the VGT control solenoid valve connector.

3.

Measure resistance between terminal 1 and 2 of the valve.

4.

Check that the resistance is within the specification.

Specification: Refer to Specification section.

Removal
1.

Turn ignition switch OFF.

2.

Disconnect the VGT control solenoid valve connector (A).

3.

Remove the VGT control solenoid valve in the direction of the arrow.

Installation
1.

Install is reverse of removal.