Remove and Installation

When the oil sensor signal fault occurs, refer to the DTC guide.

1.

Drain the engine oil.

2.

Remove the oil level sensor (A) after disconnecting the oil level sensor connector (B).

Tightening torque :

8.8 ~ 9.8N.m (0.9 ~ 1.0kgf.m, 6.5 ~ 7.2lb-ft)

3.

Installation is reverse order of removal, with a new gaskat.