Inspection
1.

Turn the ignition switch OFF.

2.

Disconnect the mode control actuator connector.

3.

Verify that the mode control actuator operates to the defog mode when connecting 12V to the terminal 3 and grounding terminal 4.

Verify that the mode control actuator operates to the vent mode when connecting in the reverse.

1. -

2. -

3. Defog mode

4. Vent mode

5. Sensor ground

6. Feedback signal

7. Sensor (+ 5V)

4.

Connect the mode control actuator connector.

5.

Turn the ignition switch ON.

6.

Check the voltage between terminal 6 and 5.

Specification

Door position

Voltage (V)

Error detecting

Max. cooling

0.3 ± 0.15V

Low voltage : 0.1V or less

Max. heating

4.7 ± 0.15V

High voltage : 4.9V or more

It will feedback current position of actuator to controls.

7.

If the measured voltage is not specification, substitute with a known-good mode control actuator and check for proper operation.

8.

If the problem is corrected, replace the mode control actuator.