Component Location
General Description

When the ID code from the transponder is verified by the ICU then the registering sequence is complete and a answer signal is sent to the EMS.

The ICU sends a START or NO START signal to the EMS.

DTC Description

The DTC will set, if the data checksum sent by EMS and ICU is different.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

CAN Data status receiving from ECM/PCM

1.

Faulty ECM/PCM

2.

Faulty ICU

Threshold value

•

Data frame error

•

Check sum error

•

Message error

Detecting time

•

1 time

DTC Erasing

Condition

•

Without a fault or using a GDS

Diagnostic Circuit Diagram
Signal Waveform & Data

Fig.1) A normal signal waveform of antenna and immobilizer communication when IG key(TP: Transponder) is OFF to ON.