Check for continuity and measure the resistance between terminals.
Standard value (Fabric / Leather)
Cushion : 4.77 Ω ± 10%
Back 4.30 Ω ± 10% / 4.13 Ω ± 10%
Set : 9.07 Ω ± 10% / 8.9 Ω ± 10%
Operate the seat heater after connecting the connector, and then check the thermostat by measuring the temperature of seat surface.
Standard value (Fabric / Leather)
Cushion : 40 ± 2℃ (104 ± 35.6°F)
Back : 46 ± 2℃ (114.8 ± 35.6°F)
Check for continuity between the terminals after disconnecting the connector.
Check for continuity and measure the resistance between No.1 and NO.3 terminals.
Standard value (Bench / Split)
Cushion : 1.53 Ω ± 10% / 4.05 Ω ± 10%
Back : 1.35 Ω ± 10%
Set : 2.88 Ω ± 10%
Operate the seat warmer after connecting the 3P connector, and then check the thermostat by measuring the temperature of seat surface.
Standard value (Bench / Split)
Cushion : 40º ± 2°C / 40º ± 2°C (104 ± 35.6°F)
Back : 46º ± 2°C (114.8 ± 35.6°F)