DTC Description

If faulty sensor "A" supply voltage is detected for more than 0.1 sec., ECM sets DTC P064300. This fault might be caused by short to power/ground in sensor supply "A" circuit or internal error of ECM.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Voltage monitoring

1.

Poor connector connection

2.

Faulty sensor "A" supply circuit

3.

Defected ECM

Enable Conditions

•

Engine running

Threshold Value

•

Faulty sensor "A" supply voltage

Diagnostic Time

•

100 msec

Fail Safe

Engine OFF

•

No

EGR Off

•

No

Torque Limit

•

Yes

MIL

•

On