If open or short in circuit of injector #3 in detected under injector operationg condition, ECM sets DTC P020300. This fault might be caused by open or short circuit in wiring of injector #3.
Item | Detecting Condition | Possible Cause | |
DTC Strategy |
•
Voltage Monitoring | 1. Poor connector connection 2. Open in circuit of injector #3 3. Short circuit in wiring of injector #3 4. Defected injector #3 | |
Enable Condition |
•
Engine running | ||
Threshold Value | Case 1 |
•
Open in injector circuit | |
Case 2 |
•
Short circuit in wiring | ||
Detecting Time |
•
- | ||
Fail Safe | Engine OFF |
•
Yes (Case 1)
•
No (Case 2) | |
EGR Off | ![]() NO | ||
Torque Limit | ![]() YES | ||
MIL |
•
On |