Terminal and Connector Inspection
1.

Many malfunctions in the electrical system are caused by poor harness and terminals.

Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.

2.

Thoroughly check all connectors (and connections) for looseness, bending, corrosion, contamination, deterioration, and/or damage.

3.

Has a problem been found?

▶ Repair as necessary and then go to "Verification of Vehicle Repair" procedure.

▶ Go to "Control Circuit Inspection" procedure.

Control Circuit Inspection
1.

Ignition switch "OFF"

2.

Connect VMI to GDS and set up the Oscilloscope.(2 Channel):

Channel A (+) : Fuel pump relay control terminal (ECM Harness Connector)

Channel A (-) : Ground

3.

Ignition switch "ON" & Engine "OFF"

4.

Inspection condition : Ignition switch "ON"

Specification :

Fuel pump operation period after ignition switch "ON" : Approx. 0V

Fuel pump non-operation period after ignition switch "ON" : Approx. 12V

5.

Is the measured value within specification?

▶ Go to "Component Inspection" procedure.

▶ Inspect and repair open or short in circuit, and then go to "Verification of Vehicle Repair" procedure.