TCM set this code When Shift Motor 2 moving is not enough Reverse gear shifting.
Item | Detecting Condition | Possible Cause |
DTC Strategy |
•
Check the engagement | 1. DCT |
Enable Conditions |
•
Shifting Reverse gear
•
Battery voltage above 10V
•
No electrical error in Shift Motor 2
•
Power of Shift Motor 2 is above 9V | |
Threshold Value |
•
Above 0.1419mm | |
Detecting Time |
•
More than 3 times | |
Fail Safe |
•
Drive Odd gear |