DTC Description

If the position sensor of VSA output voltage is above threshold value for more than 2 sec., ECM sets DTC P201700. This fault might be caused by open in signal or ground circuit or short to power in power/signal circuit of VSA position sensor.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage monitoring

1.

Short to power in power circuit of VSA position sensor

2.

Open or short to power in signal circuit of VSA position sensor

3.

Open in ground circuit of VSA position sensor

4.

Defected VSA

Enable Conditions

Engine running

Threshold Value

Position sensor of VSA output voltage is above threshold value (4800mV)

Diagnostic Time

2 sec

Fail Safe

Engine OFF

No

EGR Off

No

Torque Limit

No

MIL

Off