DPF DPS | Terminal | Inspection Condition | Measured Value | Remarks | |
Pin No. | 1 | motor(+) |
•
Ignition switch "ON" & Engine "OFF"
•
Voltage is measured on wiring side(Disconnected) | B+ | Signal Waveform (Fig. 1) |
2 | motor(-) | B+ | Signal Waveform (Fig. 2) | ||
3 | VSA F/B Power | Approx. 5V | - | ||
4 | VSA F/B Signal | Approx. 4.0V | - | ||
5 | VSA F/B Ground | 0V | - |
Fig.1) Motor + pull-up voltage value (Duty = Approx. 70%)