DTC Description

If short to ground in motor circuit is detected for more than 1 sec., ECM sets DTC P048900.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Signal monitoring

1.

Poor connector connection

2.

Short to ground in motor circuit of E-EGR actuator

3.

Defected E-EGR actuator

Enable Conditions

•

Engine running

Threshold Value

•

Short to ground in motor circuit of E-EGR actuator

Diagnostic Time

•

1 sec

Fail Safe

Engine OFF

•

No

EGR Off

•

Yes

Torque Limit

•

Yes

MIL

•

On