DTC Description

If short to ground in motor circuit is detected for more than 1 sec., ECM sets DTC P048900.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Signal monitoring

1.

Poor connector connection

2.

Short to ground in motor circuit of E-EGR actuator

3.

Defected E-EGR actuator

Enable Conditions

Engine running

Threshold Value

Short to ground in motor circuit of E-EGR actuator

Diagnostic Time

1 sec

Fail Safe

Engine OFF

No

EGR Off

Yes

Torque Limit

Yes

MIL

On