The EPB ECU checks the battery voltage and alternator output voltage to determine, as a safety issue,
whether this system can operate normally or not.
The normal battery voltage range is essential for controlling this system as intended
When hardwire ignition signal and CAN ignition signal are different, EPB ECU sets DTC
Item | Detecting Condition | Possible Cause |
DTC Strategy |
•
Comparison between hardwire and CAN ignition signal | 1. Faulty IGN signal 2. CAN IGN circuit problem 3. EPB ECU input, ground circuit, or faulty connection |
Enable conditions |
•
EPB awake, normal CAN signal, normal battery voltage range | |
Threshold value |
•
When hardwire ignition signal is low during driving for 2min | |
Fail Safe |
•
- |
Bat. Voltage | IG Key ON | ENG. ON |
Approx. 11.8 [V]~12.5 [V] | Approx. 12.5 [V] ~ 14.5 [V] |