Component Location
General Description

The Evaporator sensor is a negative temperature coefficient thermistor that is mounted at the evaporator core. The A/C ECU uses the evaporator sensor data to control A/C compressor operation in order to prevent evaporator freezing.

DTC Description

Air conditioner Control Module sets DTC B1242 if Evaporator sensor has been detected over 4.9V for 4 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Voltage check

1.

Open in signal circuit

2.

Short to battery in signal circuit

3.

Faulty Evaporator sensor

4.

Faulty Air conditioner control Unit

Enable Conditions

•

IG KEY ON

Threshold value

•

Evaporator sensor has been detected over 4.9V for 4 seconds.

Failsafe

•

Control with the value of -2℃(28.4℉)

Specification
※ Resistance value of evaporator sensor as a function of temperature.

Temperature(℃/℉)

Resistance(㏀)

Temperature(℃/℉)

Resistance(㏀)

-10/-14

18

20/68

4.8

0/32

11

30/86

3.3

10/50

7.3

40/104

2.3

Diagnostic Circuit Diagram
Яндекс.Метрика