Components | Location reference-page | ||
E01 | Left horn | ||
E02 | Right horn | ||
M01-2 | Multifunction switch | ||
M01-3 | Multifunction switch | ||
M94 | Horn switch | ||
Connectors | |||
JE01 | |||
JM09 | |||
MM10 | |||
Grounds | |||
G02 | |||
Circuit Description | |
Battery voltage is applied at all times to both the coil and the contacts of the horn relay. With the horn switch depressed, ground is provided to the coil of the horn relay through the horn switch. The relay contacts closeand apply battery voltage to the horns. The horns sound. |