INSPECTION
OPERATION CHECK

Sweden, Finland, Estonia

Norway, Iceland, Denmarks

INSPECT CIRCUITS FOR DAYTIME RUNNING LIGHT SYSTEM
1.

Disconnect the wire connector to DRL module from engine compartment.

2.

Inspect the connector on wire harness side as shown.

Check For

Test Connect

Condition

Test Specification

Continuity

5-Ground

Head lamp switch

OFF

No continuity

ON

Continuity

6-Ground

Constant

Continuity

9-Ground

Dimmer&passing switch

Head light ON

Continuity

Head light OFF

No continuity

Voltage

9-Ground

Ignition switch

ON

Battery voltage

ACC or LOCK

No voltage

5-Ground

Ignition switch

ON

Battery voltage

ACC or LOCK

No voltage

7-Ground

Constant

Battery voltage

3-Ground

Engine

Stop

No voltage

Running

Battery voltage

3.

If circuit is not as specified, refer to schematic diagram and inspect short or circuits.