Raise the vehicle and release the parking brake.
Disconnect the HECU harness connector's and measure from the harness side connector.
Be sure to remove the connector's double lock and insert the probe into the harness side (back-probe). Inserting it into the terminal side may resultin a bad connection.
Rotate the wheel to be measured approximately 1/2 to 1 rotation per second, and check the output voltage using a circuit tester or an oscilloscope.
Wheel speed sensor | Front left | Front right | Rear left | Rear right |
Terminal | 1 | 19 | 5 | 22 |
2 | 20 | 6 | 23 |
Output voltage :
When measuring with an oscilloscope : 150mV peak-to-peak or more
Connect an ohmmeter between the wheel speed sensor terminals and measure the resistance.
Service standard |
Front, Rear : 1,385 ± 110Ω |
Connect a voltmeter between the wheel speed sensor terminals and measure the voltage by turning the wheel.
Set the voltmeter to measure AC voltage.
Service standard : AC voltage detected.