INSPECTION
1.

Disconnect the switch from harness side, floor console upper cover.

2.

Connect the battery voltage between terminals 3 and 4(Reference voltage =VB).

3.

Measure the voltage between terminals 2 and 3( V).

4.

Check the percent ratio(V/VB x 100%) between voltages VB and V at each position.

Position No.

Rotation

Ratio(±5%)

Voltage(V)

0

95.5%

11.46 ± 0.5V

1

30°

83%

9.96 ± 0.5V

2

67°

68.2%

8.18 ± 0.5V

3

100°

55%

6.60 ± 0.5V

5.

If the voltage is not as specified, replace the head lamp levelling switch.