Item | Specifications | ||||
Starter | Type | PRE.engaged drive | |||
Rated voltage | 12V, 2.0KW | ||||
No. of pinion teeth | 12 | ||||
No-load charasteristics | Voltage | 11V | |||
Amperage | 130A, MAX | ||||
Speed | 3,600rpm, MIN | ||||
Commutator diameter | Standard | 35 mm (1.378 in) | |||
Limit | |||||
Undercut depth | Standard | 0.7 mm (0.028 in) | |||
Limit |
Item | Specifications | |
Alternator | Rated voltage | 12V, 120A |
Speed | 1,000 ~ 12,000 rpm | |
Voltage regulator | I.C regulator built-in type | |
Regulator setting voltage | 14.4 ± 0.3V(AT 20℃ full chgreged battery) | |
Temperrature compensation | -10 ± 3mV/°C | |
Battery | Type | CMF 80AH |
Cold cranking amperage at-18°C (0°F) | 720A | |
Reserve capacity | 160min | |
Specific gravity at 20°C (77°F) | 1.280 ± 0.01 |
COLD CRANKING AMPERAGE is the amperage a battery can deliver for 30 seconds and maintain a terminal voltage of 7.2V or greater at a specified temperature.
REVERSE CAPACITY RATING is amount of time a battery can deliver 25A and maintain a minimum terminal voltage of 10.5V at 25.7°C(77°F)
Item | Specifications | |
Glow plug | Rated voltage | DC 11V |
Current | 16A ± 1.5A after 4 seconds loading at rated voltage | |
Glow plug relay | Rated voltage | DC 12V |
Operating voltage range | DC 9V ~ DC 16V | |
Operating temperature range | -40°C ~ 120°C | |
Rated load current | DC 12V, 70A |
Items | Nm | kgf.m | lb·ft |
Generator terminal (B+) Generator mounting bolts Starter motor terminal (B+) Stater moter mounting bolts Battery terminal Glow plug Glow plug plate attaching nut | 10.8 ~ 14.7 38.2 ~ 58.8 9.8 ~ 11.8 58.8 ~ 53.9 0.4 ~ 5.9 9.8 ~ 13.7 0.8 ~ 0.15 | 1.1 ~ 1.5 3.9 ~ 6.0 1.0 ~ 1.2 4.3 ~ 5.5 0.4 ~ 0.6 1.0 ~ 1.4 0.08 ~ 0.15 | 8.0 ~ 10.8 28.2 ~ 43.4 7.2 ~ 8.7 31.1 ~ 39.8 2.9 ~ 4.3 7.2 ~ 10.1 0.6 ~ 1.1 |