INSPECTION
1.

Ignition "OFF"

2.

Disconnect the connector of temperature control actuator.

3.

Verify that the temperature control actuator operates to the hot position when connecting 12V to the terminal 4 and grounding terminal 3.

Verify that the temperature control actuator operates to the cool position when connecting in the reverse.

4.

Check the voltage between terminals 6 and 7.

[Specification]

Door position

Voltage (6-7)

Error detecting

Max. cooling

0.3 ± 0.15V

Low voltage : 0.1V or less

Max. heating

4.7 ± 0.15V

High voltage : 4.9V or more

It will feedback current position of actuator to controls.

5.

If the measured voltage is not specification, substitute with a known-good temperature control actuator and check for proper operation.

6.

If the problem is corrected, replace the temperature control actuator.