INSPECTION

The Continuously Variable Valve Timing (CVVT) system controls the amount of valve overlap by varying the amount of oil flow into an assembly mounted on the intake camshaft through PCM control of an oil control valve. As oil is directed into the chambers of the CVVT assembly, the cam phase is changed to suit various performance and emissions requirements..

1.

When camshaft rotates engine rotation-wise: Intake-Advance / Exhaust-Retard

2.

When camshaft rotates counter engine rotation-wise: Intake- Retard / Exhaust- Advance

SPECIFICATION

Item

Specification

Coil Resistance (Ω)

6.9 ~ 7.9Ω at 20℃ (68℉)

CIRCUIT DIAGRAM
(A/T)
(M/T)
COMPONENT INSPECTION
1.

Turn ignition switch OFF.

2.

Disconnect OCV connector.

3.

Measure resistance between OCV terminals 1 and 2.

4.

Check that the resistance is within the specification.

Specification: Refer to SPECIFICATION.