EPS uses an electric motor to provide directional contol to the driver. EPS CM has a charging circuit to supply current to a motor temoporarily.
EPS CM sets this code and turns on warning lamp if charged voltage is too low due to a abnormal charging circuit. At that time EPS CM inhibits it's own function.
Item | Detecting Condition | Possible cause |
DTC Strategy | ● Check voltage | ● Poor connetion in power circuit ● Poor connection in ground circuit ● Over charging |
Enable conditions | ● IG ON | |
Threshold value | ● Charging circuit voltage too low | |
Fail Safe | ● Waring lamp ON, EPS control is inhibited | |
Restoration conditions | ● Normal condition after IG on → off |
Bat. Voltage | IG Key ON | ENG. ON |
Approx. 11.8 [V]~12.5 [V] | Approx. 12.5 [V] ~ 14.5 [V] |