Component Location
General Description

EPS uses an electric motor to provide directional contol to the driver. An electric mortor consumes much current during operating. It can be overheat under excessive use, at that time EPS CM restricts motor current for protecting EPS from unexpected problem.

DTC Description

EPS CM sets this code If temperature of EPS CM is higher than 85℃ (185℉) due to excessive use.

EPS CM restricts assist steering function to decrease motor current.

EPS CM inhibits assist steering if temperature of EPS CM is higher than 120℃ (248℉).

DTC Detecting Condition

Item

Detecting Condition

Possible cause

DTC Strategy

● Check motor temperature

● Continous Steering operation

Enable conditions

● IG ON & Engine ON

Threshold value

● Temperature of EPS CM > 85℃ (185℉).

Fail Safe

● The power of EPS is restricted.

Restoration conditions

● Temperature of EPS CM < 85℃ (185℉).

Яндекс.Метрика