Component Location
General Description

The automatic transmission fluid(ATF) temperature sensor is installed in the Valve Body. This sensor uses a thermistor whose resistance changes according to the temperature changes. The TCM supplies a 5V reference voltage to the sensor, and the output voltage of the sensor changes when the ATF temperature varies. The automatic transmission fluid(ATF) temperature provides very important data for the TCM’s control of the Torque Converter Clutch, and is also used for many other purposes.

DTC Description

This DTC code is set when the ATF temperature output voltage is lower than a value generated by thermistor resistance, in a normal operating range, for approximately 1 second or longer. The TCM regards the ATF temperature as fixed at a value of 80 °C.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Electrical Check

Open in circuit

Faulty sensor

Faulty PCM

Case 1

Enable Conditions

ATF temperature(IG ON) ≥ -38℃

Threshold Value

Voltage > 4.8V

Case 2

Enable Conditions

ATF temperature(IG ON) ≥ -38℃

Threshold Value

4.547V < Voltage < 4.8V

Case 3

Enable Conditions

ATF temperature(IG ON) ≤ -39℃

Engine speed > 1000rpm

Output Speed ≥ 500rpm

Engine Coolant Temperature ≥ 70℃

Time Delay = 160 sec

Threshold Value

Voltage > 4.547V

Diagnostic Time

More than 1sec.

Fail Safe

Learning control and Intelligent shift are inhibited

Fluid temperature is regarded as 80℃

Specification

Temperature ℃(℉)

Resistance (㏀)

Temperature ℃(℉)

Resistance (kΩ)

-40(-40)

139.5

80(176)

1.08

-20(-4)

47.7

100(212)

0.63

0(32)

18.6

120(248)

0.38

20(68)

8.1

140(284)

0.25

40(104)

3.8

160(320)

0.16

60(140)

1.98

Diagnostic Circuit Diagram