Monitor Scantool Data
1.

Connect scantool to data link connector(DLC)

2.

Engine "ON" .

3.

Monitor the "VF SOL. VALVE" parameter on the scantool

4.

Shift gear at each position .

Fig 1) "P,N"

Fig 2) "R"

Fig 3) "1st" grar

Fig 4) "2nd" gear

Fig 5) "3rd" gear

Fig 6) "4th" gear

5.

Does "ON/OFF SOL VALVE" follow the referance data?

▶ Fault is intermittent caused by poor contact in the sensor's and/or PCM/TCM's connector or was repaired and PCM/TCM memory was not cleared. Throughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration or damage.Repair or replace as necessary and go to "Verification Vehicle Repair" procedure .

▶ Go to "W/Harness Inspection " procedure.