Component Location
General Description

The automatic TRANSAXLE fluid(ATF) temperature sensor is installed in the Valve Body. This sensor uses a thermistor whose resistance changes according to the temperature changes. The TCM supplies a 5V reference voltage to the sensor, and the output voltage of the sensor changes when the ATF temperature varies. The automatic transmission fluid(ATF) temperature provides very important data for the TCM's control of the Torque Converter Clutch, and is also used for many other purposes.

DTC Description

This DTC code is set when the ATF temperature output voltage is higher than a value generated by thermistor resistance, in a normal operating range, for an extended period of time . The TCM regards the ATF temperature as fixed at a value of 80 ℃.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Check for Voltage range

Sensor signal circuit is short to ground

Faulty sensor

Enable Conditions

Always

Threshold Value

Voltage ≥4.9V

Diagnostic Time

More than 1sec

Fail Safe

Learning control and Intelligent shift are inhibited.

Fluid temperature is regarded as 80°C

Specification

TEMP.(℉)

RESISTANCE(kΩ)

TEMP.(℉)

RESISTANCE(kΩ)

-40(-40℉)

139.5

80(176℉)

1.08

-20(-4℉)

47.7

100(212℉)

0.63

0(32℉)

18.6

120(248℉)

0.38

20(68℉)

8.1

140(284℉)

0.25

40(104℉)

3.8

160(320℉)

0.16

60(140℉)

1.98

Schematic Circuit Diagram
Яндекс.Метрика