Component Location
General Description

The Air mix actuator(Temperature actuator) located at heater unit. It contains temp motor that changes temp door position and potentiometer that monitors position of temp door. The Air mix actuator(Temperature actuator) regulates the temperature by the procedure as follows. Signal from control unit adjusts position of temp door by operating temp motor and then temperature will be regulated by the hot/cold air ratio decided by position of temp door. In operation, potentiometer delivers temp door position transformed into voltage value to A/C ECU .

DTC Description

The ECM sets DTC B1265 if there is a short to power in the DR Direction(VENT) actuator signal harness.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

● Voltage check

● Open circuit in harness

● Short circuit in harness

● Faulty DR Direction(VENT) actuator

Threshold value

● >4.9V

Detecting time

● 0.3sec

FAIL SAFE

● Setting mode : VENT

Fix at VENT position

● Setting mode : Except VENT

Fix at DEF position

Schematic Diagram
Signal Waveform

※ Voltage value of Air Mix potentiometer as a function of temp door position.

Door position

Voltage

Error Detecting Condition

VENT

0.3±0.15V

Undervoltage : 0.10V or less

DEF

4.7±0.15V

Overvoltage : 4.92V or more