Component Location
General Description

The ambient temperature sensor located at the center stay of the condensor detects ambient air temperature. It is joined to AQS sensor as one boby. It is a negative type thermistor whose resistance is inversely proportional to temperature. Its output is used for sensor fail-safe, temperature regulation door lock, blower motor level control, mix mode control and in-car humidity control.

DTC Description

The ECM sets DTC B1237 if there is a short circuit in ambient temp sensor signal harness or the measured voltage value of the sensor is less than the threshold value(0.1V)

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

● Voltage check

● Short circuit in harness

● Faulty ambient temp.sensor

● Faulty A/C Control Unit

Threshold value

●< 0.1V

Detecting time

● 0.3sec

FAIL SAFE

● Control with the value of 20℃

Schematic Diagram
Signal Waveform

※ Resistance value of ambient temp.sensor as a function of temperature.

Temperature(℃)

Resistance(㏀)

Temperature(℃)

Resistance(㏀)

-20

271.1

50

10.9

0

95.1

60

7.5

25

30.0