Terminal and Connector Inspection
1.

Many malfunctions in the electrical system are caused by poor harness and terminals.

Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.

2.

Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.

3.

Has a problem been found?

YES

a.

Repair as necessary and go to "Verification Vehicle Repair" procedure.

NO

a.

Go to "W/Harness Inspection" procedure.

Signal Circuit Inspection
Check for short in harness
1.

Ignition "OFF".

2.

Disconnect DR Direction(VENT) Actuator.

3.

Measure resistance between terminal "6" and "7" of Direction potentiometer.

1)

Specification :Approx. 0 Ω

4.

Is the measured resistance within specifications?

YES

a.

Go to "Ground circuit Inspection " procedure.

NO

a.

Check for open in signal harness. Repair as necessary and go to "Verification of Vehicle Repair" procedure.

Ground Circuit inspection
Check for open in ground harness
1.

Ignition "ON".

2.

Connect DR Direction(VENT) Actuator.

3.

Measure resistance between terminal "5" of Direction Actuator and chassis ground.

1)

Specification :Approx. 0 Ω

4.

Is the measured resistance within specifications?

YES

a.

Go to "Component Inspection " procedure.

NO

a.

Check for open in harness. Repair as necessary and go to "Verification of Vehicle Repair" procedure.