Component Inspection
1.

Ignition "OFF"

2.

Disconnect ISCA valve connector

3.

Measure resistance between terminals 2 and 3 of the valve connector(Component side)

1)

Specification

Temperature

Closing Coil(Ω)

20℃(68℉)

14.6~16.2

4.

Is resistance within the specification?

YES

a.

Go to next step as below

NO

a.

Check ISCA for contamination, deterioration, or damage. Substitute with a known-good ISCA and check for proper operation. If the problem is corrected, replace ISCA and then go to "Verification of Vehicle Repair" procedure