Ignition "OFF"
Disconnect oil control valve connector
Measure resistance between terminals 1 and 2 of the solenoid connector(Component side).
Specification
Temp.(°C) | Temp.(°F) | Resistance (Ω) | Temp.(°C) | Temp.(°F) | Resistance (Ω) |
0 | 32 | 6.2 ~ 7.4 | 60 | 140 | 8.0 ~ 9.2 |
10 | 50 | 6.5 ~ 7.7 | 70 | 158 | 8.3 ~ 9.5 |
20 | 68 | 6.9 ~ 7.9 | 80 | 176 | 8.6 ~ 9.8 |
30 | 86 | 7.1 ~ 8.3 | 90 | 194 | 8.9 ~ 10.1 |
40 | 104 | 7.4 ~ 8.6 | 100 | 212 | 9.2 ~ 10.4 |
50 | 122 | 7.7 ~ 8.9 |
Is resistance within specification?
YES
▶ Go to next step as below
NO
▶ Check oil control valve for contamination, deterioration, or damage. Substitute with a known-good solenoid and check for proper operation. If the problem is corrected, replace solenoid and then go to "Verification of Vehicle Repair" procedure