Component Location
General Description

In order to control emissions of the CO, HC and NOx components of the exhaust gas, heated oxygen sensor (HO2S), mounted on the front side and rear side of catalytic converter, detects the oxygen content in the exhaust gas. The front HO2S signal is used to control air/fuel ratio (closed loop fuel control) and the rear HO2S signal is used to monitor front HO2S and catalyst for proper operation.

The HO2S requires a minimum temperature to operate properly and provide a closed loop fuel control system. The HO2S contains the heater element to reduce its warming-up time and ensure its performance during all driving conditions.

The ECM controls this heater element by duty cycle. The main relay supplies voltage to the heater and the ECM provides a ground circuit for activating the heater.

DTC Description

When ECM detects short to power in the heater control circuit(B1S1), ECM sets DTC P0032.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

● Heater check high

● Poor connection

● Short to battery in control circuit

● B1S1

Enable Conditions

Threshold Value

● Short to battery

Diagnostic Time

● Continuous

MIL ON Condition

● 2 driving cycle

※ B1S1 : upstream oxygen sensor / B1S2 : downstream oxygen sensor

Specification

ITEM

Specification

Heater Resistance(Ω)

Approx. 9.0Ω(20℃)

Schematic Diagram
note
To view Flash content, you need to install the appropriate browser extension
Signal Waveform
Яндекс.Метрика