Component Inspection
1.

IG KEY "OFF", ENGINE "OFF".

2.

Disconnect APTS connector, VSCA connector, DPS connector and ECTS connector.

3.

Check that sensor connector power supply is within the specification after turning IG KEY "ON".

4.

Connect APTS connector and VSCA connector, DPS connector, ECTS connector in turn.

5.

Measure the voltage of power circuit of each sensor with all connector connected.

1)

Specification :

APTS, VSCA, DPS : Sensor power supply should not change as connecting APTS connector, VSCA connector, DPS connector.( If the change of sensor power supply occur as connecting sensor connector, this means the occurrence of short inside of sensor.)

ECTS : Connecting ECTS connector terminal, signal voltage is outputted from 0.6V to 4.5V depending on ECTS tempt. (While connector is being connected, if output voltage rises or no DTC is outputted, the sensor component is considered as normal one.)

6.

Does change of sensor power supply occur as connecting sensor connector?

YES

a.

Replace related sensors.(APTS/VSCA/DPS/ECTS)

NO

a.

Go to "Verification of Vehicle Repair".