Component Location
General Description

Lambda sensor installed at exhaust manifold is planar ZrO2 dual cell type and it senses O2 density of exhaust gas for accurate EGR control through fuel correction. It also limits smoke which is generated by reach air-fuel mixture at engine maximum loading condition. ECM controls pumping current in order to fit λ-value from linear O2 sensor to 1.0.

【Lean air-fuel mixture(1.0<λ<1.1)】ECM supplies pumping current to Lambda sensor (+pumping current) and activates it for Lambda sensor to have the characteristic at λ=1.0 (0.0 pumping current). With the value of pumping current supplied to Lambda sensor, ECM detects O2 density of exhaust gas.

【Rich air-fuel mixture(0.9<λ<1.0)】ECM takes away pumping current from O2 sensor (-pumping current) and deactivates it for Lambda sensor to have the characteristic at λ=1.0 (0.0 pumping current). With the value of pumping current taken away from Lambda sensor, ECM detects O2 density of exhaust gas.

This performance is the most active and fast at normal operating temp.(450℃~600℃) thus, in order to reach normal operating temp. and last at that temp., heater(heating coil) is integrated with Lambda sensor.

Heater coil is controlled by ECM as PWM. the resistance of heater coil is low when coil is cold thus, current through it increases while resistance is high when coil is hot thus, current decreases. With this principle, Lambda sensor temp. is measured and Lambda sensor heater operation varies based on the data.

DTC Description

P0031 is set when open or short to ground in Lambda sensor control circuit is detected for more than 5 sec. at Lambda sensor heater control condition. This code is due to 1)open or short to ground in heater control circuit or 2)Lambda sensor heater internal short.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

● Voltage monitoring

● Lambda sensor heater circuit

● Lambda sensor component

Enable Conditions

● Engine running

Threshold Value

● Short to GND in Lambda sensor heater control circuit

● Open in Lambda sensor heater control circuit

Diagnostic Time

● 5 sec.

Fail Safe

Fuel Cut

NO

EGR Off

NO

Fuel Limit

NO

Check Lamp

OFF

Specification

Temperature (℃)

Heater resistance (Ω)

Temperature (℃)

Heater resistance (Ω)

20

9.2

400

17.7

100 Hz

100

10.7

500

19.2

200

13.1

600

20.7

300

14.6

700

22.5

Schematic Diagram