Component Inspection
1.

Check IATS resistance

(1)

IG "OFF".

(2)

Disconnect IATS connector.

(3)

Measure resistance between terminal 3 and 4 of IATS connector(Component Side)

1)

Specification :

Temp.[℃]

Resistance [Ω]

Temp.[℃]

Resistance [Ω]

-40±1

40931~ 48352

60±1

543 ~ 616

-20±1

13890 ~ 16025

70±1

396 ~ 452

0±1

5384 ~ 6085

80±1

294 ~ 337

20±1

2311 ~ 2565

90±1

221 ~ 256

30±1

1564 ~ 1736

100±1

169 ~ 196

40±1

1077 ~ 1205

110±1

130 ~ 153

50±1

758 ~ 854

120±1

102 ~ 120

(4)

Is the measured resistance within specification ?

YES

a.

Many malfunctions in the electrical system are caused by poor harness(es) and terminals. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage. So, check poor connections and the related circuit between ECM and component thoroughly. Repair as necessary and go to "Verification of Vehicle Repair" procedure.

NO

a.

Substitute with a known - good IATS and check for proper operation.

If the problem is corrected, replace IATS and go to "Verification of Vehicle Repair" procedure.