EPS CM monitors internal circuit to protect abnormal operation. This test includes hardware (MCU, RAM, ROM and so on) test.
EPS CM checks operating condition of H/W periodically. EPS CM sets this code and turns on warning lamp if there is a fault in H/W. At that time EPS CM inhibits EPS opreation.
Item | Detecting Condition | Possible cause |
DTC Strategy | ● Check ECU H/W | ● Faulty MCU ● Faulty memory |
Enable conditions | ● IG ON | |
Threshold value | ● ECU H/W error occurs | |
Fail Safe | ● EPS warning lamp "ON", EPS control is inhibited | |
Restoration conditions | ● Normal condition after IG on → off |