Monitor Scantool Data
1.

Connect scantool to Data Link Connector(DLC).

2.

IG "ON".

3.

Select "DTC" button, and then Press "DTC Status" to check DTC's information from the DTCs menu.

4.

Read "DTC Status" parameter.

5.

Is parameter displayed "Present fault"? 

▶ Go to "Terminal and Connector inspection" procedure.

▶ Fault is intermittent caused by poor contact in the sensor’s and/or ECM’s connector or was

repaired and ECM memory was not cleared. Thoroughly check connectors for looseness, poor

connection, bending, corrosion, contamination, deterioration, or damage. Repair or replace as

necessary and go to "Verification of vehicle Repair" procedure.