Terminal and Connector Inspection
1.

Many malfunctions in the electrical system are caused by poor harness and terminals.

Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.

2.

Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.

3.

Has a problem been found?

▶ Repair as necessary and go to "Verification of Vehicle Repair" procedure.

▶ Go to "Starter Relay circuit inspection" procedure.

Control Circuit Inspection
■ Check Short in control circuit
1.

IG KEY "OFF".

2.

Disconnect Starter Relay.

3.

IG KEY "ON"

4.

Measure the voltage between control terminal of Starter Relay harness connector and chassis ground.

Specification : Approx 4.3V

5.

Is the measured voltage within specification ?

▶ Go to "Component inspection" procedure.

▶ Repair Short to ground in control circuit, and go to "Verification of vehicle Repair" procedure.