Componet Location
General Description

The Air Mix actuator contains a motor that changes temp door position and a potentiometer that monitors position of temp door. The Air mix actuator(Temperature actuator) regulates the temperature by operating temp door motor. The potentiometer delivers temp door position to the A/C ECU .

DTC Description

The Air conditioner Control Module sets DTC B1245 if Feedback signal of Driver Air mix actuator(Temperature actuator) has been detected open or below 0.1V for 0.3 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible cause

DTC Strategy

•

Voltage check

•

Poor Conection in harness

•

Open in signal(Feedback signal), power and ground circuit

•

Faulty Driver Temperature Actuator

•

Faulty Air condition Contorl Module

Enable Conditions

•

IG KEY ON

Threshold value

•

Feedback signal of Driver Air mix actuator(Temperature actuator) has been detected open or below 0.1V for 0.3 seconds

Failsafe

•

Setting temperature : 63℉-76.1℉, fix at max. cooling position

•

Setting temperature : 77℉-89.6℉, fix at max. heating position

Specification
※ Voltage value of Air Mix potentiometer as a function of temp door position.

Door position

Voltage

Max. cool

0.3±0.15V

Max. warm

4.7±0.15V

Diagnostic Circuit Diagram