Inspection
1.

Disconnect the negative (-) battery terminal.

2.

Remove the crash pad lower panel.

(Refer to Body group - "Crash pad")

3.

Remove the junction box.

4.

Check for continuity between the terminals.

5.

There should be continuity between the No.2 in the I/P-F and No.17 terminal in the I/P-B when power and ground are connected to the No.2 terminal in the I/P-H and No.17 terminal in the I/P-B.

6.

There should be no continuity between the No.2 terminal in the I/P-F and No.17 terminal in the I/P-B when power is disconnected.